Request a consultation Menu

Through-wall · Wine Master

Wine Master C25X wine cellar cooling unit

A compact through-wall cooling unit for wine cellars of up to 25 m³. It cools the cellar and exhausts warm air into an adjacent ventilated room or outside.

Versions

  • C25 X – cooling
  • C25 SX – cooling and heating
  • C25 SRX – heating and compressor heating
Price from CZK 79,934 incl. VAT
  • OutdoorsCZK 106,536
  • IndoorsCZK 79,934
  • With heatingCZK 94,695
Price for the product only – excluding installation, delivery and building work. We confirm availability in our quotation.

Documents

We’ll help you choose a cooling unit

Technical specifications

Specifications

Cooled space (max.)
25 m3 with insulation to the manufacturer’s specification
Installation type
through-wall
Cooling capacity
550 W at 15 °C
Power consumption
400 W
Temperature setting
8–18 °C (factory setting 12 °C)
Max. temperature in the heat exhaust space
35 °C
Noise level
45 dB (1 m) / 40 dB (3 m)
Dimensions (W × H × D)
54 × 38 × 52.4 cm
Weight
27 kg
Refrigerant
R290
Power supply
230–240 V, 50 Hz, 3 m cable
Warranty
2 years

Specifications based on the manufacturer’s documentation.

Description

About the product

The Wine C25 X is installed in an opening in the wall between the cellar and an adjacent space. It cools on the cellar side and exhausts warm air on the other – approximately 15 °C warmer than the air it draws in. The space behind the wall must therefore be ventilated: ideally around 20 °C, max. 35 °C for short periods. If warm air is not suitable for the adjacent room, a ducted or split solution is more appropriate.

Versions according to the manufacturer:

  • C25 X – cooling only
  • C25 SX – cooling and heating (250 W heating element) for cellars where the temperature drops in winter
  • C25 SRX – additionally with compressor heating for cold conditions on the heat exhaust side

Factory setting 12 °C, range 8–18 °C. Installed in a wooden mounting frame; condensate drains through a hose. The dust filter is changed as needed, at least once a year. The unit requires a dedicated circuit breaker of at least 16 A.

According to the manufacturer, the maximum volume applies only to a space insulated according to the table in the manual (all walls, ceiling, floor and door). Glazing, adjacent heated rooms and frequent door opening increase the capacity required – so we choose a suitable unit for the specific space.

The cooling unit cools and stabilises temperature; it does not control humidity on its own. Stable humidity comes mainly from the insulation and airtightness of the space; for humidifying or dehumidifying, the manufacturer offers separate devices.

More products

Through-wall

Advice

Need help choosing?

We choose cooling capacity and racking type according to the volume and insulation of the room. Send us the dimensions of the space and we will propose a suitable solution.