Wine Master cooling unit types

Wine Master cooling units for wine cellars and display cabinets from 15 to 100 m³, grouped by installation method. We choose the type according to volume, insulation and where the heat can be dissipated.

A Wine Master IN25 X cooling unit mounted on the wall of a wine cellar with connected air ducts
Wine Master installation · manufacturer’s photographIN25 X in a wine cellar

01 / How to choose

It depends on the space, the insulation and where the heat can go

Wine cellar cooling units are designed for continuous operation in the 8–18 °C range. An ordinary air conditioner usually cannot hold 12–16 °C over the long term, while an industrial unit dries the air.

  • 01

    Volume and insulation

    The stated volume applies to a space insulated to the manufacturer’s specification. How large is the space in m³, and can it be insulated from the inside?

  • 02

    Unit location

    Should the cooling unit be inside the cellar, in an adjacent room or outdoors?

  • 03

    Heat dissipation

    Can the adjacent ventilated room take warm air? Can ducts or a refrigerant line be run outside (for split units usually up to 15–20 m, depending on the model)?

  • 04

    Building preparation

    • Condensate drain
    • Dedicated circuit breaker
    • Data cable for monitoring

02 / Through-wall

Through-wall

The unit is fitted into an opening in the wall: on one side it cools the cellar, on the other it exhausts warm air into a ventilated room or through an external wall to the outside. With correct insulation, for cellars of up to 50 m³.

All through-wall cooling units

03 / Ducted

Unit inside the cellar or outdoors

IN models stand in the cellar and exhaust warm air through insulated ducts to the outside or into a ventilated room. The OUT25 X stands outside the cellar, with only insulated ducts running into the room.

All ducted cooling units

04 / Split

With an outdoor unit

The compressor stands outdoors or in an adjacent room and is connected to the indoor unit by a refrigerant line. Only the indoor unit is in the cellar – wall-mounted or, for the largest model, floor-standing.

All split cooling units

05 / Ceiling-mounted and ducted

Equipment concealed in the ceiling or behind a wall

Split units that barely affect the cellar’s design: the indoor unit sits in the ceiling, or stands outside the cellar with air ducted in.

All ceiling-mounted cooling units

06 / Small spaces

Display cabinets and small cellars

For climate-controlled display cabinets and wine cupboards, a unit in the cabinet ceiling; for a small cellar, an insulated door with a built-in cooling unit.

07 / Insulation

Separate the cellar from the rest of the house

Masonry insulation can easily be replaced today by modern insulating materials; what matters are thermal properties and water absorption. We most often use Perimeter boards, or extruded polystyrene.

In a properly insulated cellar the temperature is stable and the cooling unit’s energy consumption falls significantly. Wine Master cooling units do not control humidity on their own: stability comes mainly from the insulation and airtightness of the space; for humidifying or dehumidifying, the manufacturer offers separate devices.

Wine Master cooling units are made in France, in Colmar, Alsace.

Consultation

Not sure which type suits you?

Send us the dimensions of the space, some photographs and details of where the heat can go. We will recommend a suitable model and prepare a quotation.