Request a consultation Menu

Ducted · Wine Master

Wine Master IN25 X wine cellar cooling unit

A cooling unit installed inside cellars of up to 25 m³. It exhausts warm air through insulated ducts to the outside or into a ventilated room.

Price CZK 109,488 incl. VAT Price for the product only – excluding installation, delivery and building work. We confirm availability in our quotation.

Documents

We’ll help you choose a cooling unit

Technical specifications

Specifications

Cooled space (max.)
25 m3 with insulation to the manufacturer’s specification
Installation type
in the cellar, heat exhausted via ducts
Cooling capacity
500 W at 15 °C
Power consumption
450 W
Heating
250 W
Temperature setting
8–18 °C (factory setting 12 °C)
Max. intake air temperature
35 °C
Noise level in the cellar
43 dB (1 m) / 38 dB (3 m)
Dimensions (W × H × D)
54 × 54 × 63 cm
Weight
35 kg
Refrigerant
R290
Condensate drain
2 m hose
Warranty
2 years

Specifications based on the manufacturer’s documentation.

Description

About the product

The Wine IN25 X stands on brackets inside the cellar and draws in and exhausts air for heat dissipation through two insulated ducts. Only grilles are visible on the façade or in the adjacent room. It suits situations where a through-wall connection to a suitable room is not possible and you do not want an outdoor unit.

Manufacturer’s ducting requirements:

  • total length of both ducts max. 14 m in a straight line, 1 m less for each bend
  • bend radius at least 175 mm; do not reduce the duct diameter
  • intake and exhaust at least 1,000 mm apart; do not cover the ducts

Factory setting 12 °C, range 8–18 °C, 250 W heating. Condensate drains through a hose. The manufacturer offers an installation kit with insulated ducting and telescopic wall sleeves; non-original accessories may not guarantee correct operation. Circuit breaker min. 16 A.

According to the manufacturer, the maximum volume applies only to a space insulated according to the table in the manual (all walls, ceiling, floor and door). Glazing, adjacent heated rooms and frequent door opening increase the capacity required – so we choose a suitable unit for the specific space.

The cooling unit cools and stabilises temperature; it does not control humidity on its own. Stable humidity comes mainly from the insulation and airtightness of the space; for humidifying or dehumidifying, the manufacturer offers separate devices.

More products

Ducted

Advice

Need help choosing?

We choose cooling capacity and racking type according to the volume and insulation of the room. Send us the dimensions of the space and we will propose a suitable solution.