How to prepare a building for a wine cellar
Before a wine cellar is installed, five things need to be in place: thermal insulation designed for the specific building, a route for dissipating heat from the cooling unit, a condensate drain, a dedicated electrical circuit and a floor that can carry full racks. The sooner these are resolved, the cheaper and cleaner the installation.
01
Checklist
| Area | What to prepare | Why |
|---|---|---|
| Insulation | build-up designed for the building and adjacent spaces; for Wine Master cooling units, the manufacturer’s thickness table for all surfaces – tables | a condition of performance; for Wine Master, according to the manual, also of the warranty |
| Heat dissipation | a ventilated room (ideally around 20 °C, max. 35 °C for short periods), a duct route to the outside, or a location for an outdoor unit | the cooling unit exhausts air roughly 15 °C warmer than it draws in |
| Outdoor unit | outdoors out of direct sunlight, or in a ventilated room of at least 20 m³; for the SP40, max. 20 m pipe run and max. 10 m height difference | split unit manufacturer’s requirements |
| Condensate | a drain with a fall, or space for a pump or container; access for inspection | water is produced during cooling and defrosting |
| Electrics | a dedicated circuit breaker (min. 16 A for many models), a supply to the unit, a lighting circuit, and optionally a data cable | safe operation and monitoring |
| Floor | load-bearing capacity for full racks; if the floor is insulated, insulation with compressive strength and a load-spreading board | 500 bottles weigh roughly 0.6–0.8 t |
| Heating | disable underfloor heating in the cellar, insulate heating pipes | a hidden heat source |
| Penetrations | openings for pipes, cables and the drain, sealed | continuity and airtightness of the insulation |
| Access | for installing racks and glass, and for servicing the cooling unit | filter change at least once a year |
SP40 and SP80 split cooling units require a cooled space of at least 6 m³.
02
What to decide at the design stage
- the cellar’s orientation and its position relative to the boiler room, bedrooms and neighbours
- how much glass there will be, and what type of glazing
- the type of cooling unit – this determines duct routes, the outdoor unit location and any suspended ceiling
- the insulation thickness, which will reduce the internal dimensions of the room
03
Who does what
Building work – insulation, electrics, drainage and penetrations – is usually carried out by the main contractor to our specification, or by agreement we include it in our scope. We supply the technical design, furniture, cooling unit and installation. The division of work is always set out in our quotation. If you are an architect, see our For architects and designers page.
04
Sources
Technical data are based on the manufacturer’s current documentation: winemaster.fr and Wine Master manuals (IN25 X, version 07/2025, SP40 CA PRO, version 07/2025, SP40 DU PRO, version 14/2025). All manuals are available in the Documents section. The values are the manufacturer’s minimum requirements and do not replace a design for a specific building.
05 / Related
Continue
06 / Questions
Frequently asked questions
Can a wine cellar be added to an existing house?
Yes. Insulation can be applied from the inside and the cooling unit chosen according to where the heat can be dissipated. You will, however, need to allow for smaller internal dimensions and for finding service routes through existing structures.
Does a wine cellar need a drain?
For most cooling units, yes – condensate runs through a hose into a drain, or into a pump or container. The exception is the ARM15 X display cabinet unit, which evaporates condensate.
Enquiry
Send us a photograph of your space.
A short description, dimensions or a floor plan is enough for an initial assessment. We usually reply within one working day.